SUMMARY OF CATEGORY-5 APPROACH TO SPECIFICATIONS (A WORK IN PROGRESS)

REFERENCING SITE RISKS AND MATERIALS/SYSTEMS PERFORMANCE

Estimated chances of a weather event’s recurrence within next 30 years per FWS

(“Flood Return” Nat’l Weather Service calculator @ https://www.weather.gov/epz/wxcalc_floodperiod)

  • 25-year event = 70.6% chance of occurrence 

  • 50-year event = 45.5% chance etc.

  • 100-year event = 26% chance etc.

  • 500-year event = 5.8% chance etc.


—-----------------------------------------------------------------------------------

GNERAL SITE RISKS

As aggravating factors and in hybrid risks

Water courses

Geographic aerodynamics 

Flammables: types and proximities

Special Hybridities: (wind/fire or wind/flood/etc)

—-----------------------------------------------------------------------------------

DELUGE RISKS

Aggravating factors

Special Hybridities: (wind/fire or wind/flood/etc) See Isopluvial Map

Low: NWS risk of 500 year storm recurrence w/ 100-year 24-hour Isopluvial < 12”

Medium: NWS risk of 100-year storm recurrence w/ 100-year 24-hour Isopluvial = 12-16”

High: NWS risk of 100-year storm recurrence w/ 100-year 24-hour Isopluvial = 16-18”

Very High: NWS risk of 100-year storm recurrence w/ 100-year 24-hour Isopluvial = 18”+

All self sealing fasteners in all exterior assemblies for weather, thermal and fire protection; use specialty EIFS anchors

—-----------------------------------------------------------------------------------

FLOOD RISKS

Aggravating factors

Risk Hybridity (wind/fire or wind/flood/etc)

(Coastal National Risk Index county values)

Low flood risk: NWS risk of 500 year flood recurrence within next 30 years& CNRI Flooding Index < 30

Mezzanine bottom raised to 30” minimum

Exterior walls open below mezzanine

Interior walls N/A

Roof N/A

Special Hybridities:

Rainfall HIGH

Flood N/A

Fire N/A

Drought LOW

Medium flood risk:

NWS risk of 100-year flood recurrence & CNRI Coastal Flooding Index > 50

Mezzanine top raised to 60” minimum

Exterior walls open below mezzanine

Interior walls N/A

Roof N/A

Special Hybridities:

Rainfall HIGH

Flood N/A

Fire MODERATE

Drought MODERATE

High flood risk:

NWS risk of 25-year flood recurrence & CNRI Coastal Flooding Index > 80

Mezzanine top raised to 60”+ minimum

Exterior walls open below mezzanine

Interior walls N/A

Roof N/A

Special Hybridities:

Rainfall HIGH

Flood N/A

Fire HIGH (can create loose topsoil & potential for movement)

Drought HIGH

—-----------------------------------------------------------------------------------

WINDSTORM RISK

Risk Hybridity (H = wind/fire or wind/flood/etc)

Special Hybridities:

Rainfall HIGH

Flood N/A

Fire HIGH

Drought N/A

Low windstorm risk:

Structure to Category 1-2 per context

Mezzanine wood nonrated

Exterior walls wood liner nonrated

Interior walls wood nonrated

Roof N/A

Medium windstorm risk:

Structure to Category 3-4 per context

Mezzanine wood nonrated/protected

Exterior walls wood liner nonrated; openings w/impact units (C )

Interior walls wood nonrated

Roof has tiedowns

High windstorm risk: Structure to Category 5

Mezzanine wood nonrated/protected

Exterior walls wood liner nonrated; openings reinforced w/impact units (D)

Interior walls wood nonrated

Roof has tiedowns

—-----------------------------------------------------------------------------------

FIRE RISK

[Recommendedparameters for either High or Low risk] with aggravating factors

Note:

“Sheathed” = nonflammable sheathing

“Sheathed” = protective materials incorporated to insulate element(s) from fire

“Protected” = similar to a tested assembly; may be installed wholly or partially, w/ bias to protect structure (not occupants)

“Tempered” = all glass tempered

Special Hybridities: (ALL CLASSES)

Rainfall MEDIUM (see Flood)

Flood HIGH (later regrowth after drought = + fuel)

Wind HIGH

Drought HIGH

Low Fire Risk:

Low probability/Low intensity

All exterior parts/finishes non-flammable/sheathed

No protected assemblies, sheathing @ all exteriors

All exterior decks non-flammable (aluminum)

Moderate Fire Risk:

Moderate probability/Low intensity

Parts of structure protected

Mezzanine trusses (wooden) sheathed/protected

Exterior wall liner (wooden) not sheathed/not protected; openings rated

Interior walls (wooden) not protected

Roof and exterior soffits sheathed/not protected

All exterior decks non-flammable (aluminum)

High Fire Risk:

High probability/High intensity

Most of structure protected

Mezzanine trusses (metal) sheathed/protected

Exterior walls liner (metal) protected; openings rated 

Interior walls (metal) not protected

Roof and exterior soffits sheathed/not protected

All exterior decks non-flammable (aluminum)

Real time irrigated roof and walls

—-----------------------------------------------------------------------------------

THERMAL RISK

Special Hybridities (wind/fire or wind/flood/etc)

Insulate to prevent Moisture build up and keep dew point outside building (walls)

—-----------------------------------------------------------------------------------

DROUGHT RISK

Special Hybridities (wind/fire or wind/flood/etc)